Gentec thermostatic tapware comprises Lead-Free DZR Brass, chrome-plated, laminar-flow point-of-use taps engineered for Australian commercial, healthcare and aged care applications where AS 3718:2021 compliance, scald prevention under AS 4032.1, and Lead-Free WaterMark certification under NCC 2022 are required.
Gentec thermostatic tapware provides Australian healthcare, aged care, education and commercial specifiers with point-of-use thermostatic mixing taps combining precision scald protection with Lead-Free WaterMark certification under NCC 2022. Manufactured from dezincification-resistant (DZR) brass with a chrome-plated finish and laminar-flow outlet, the range integrates a thermostatic cartridge directly into the tap body, delivering mixed water at a preset safe temperature without a separate zone valve. The laminar outlet reduces aerosol generation at the point of use, a clinically relevant specification for patient-facing basins in hospital and aged care environments. For the complete TEMPSET model family, see TEMPSET Lead-Free Brass Tapware; for zone-level thermostatic mixing valves with NSW Health Approval, see Thermostatic Mixing Valves and FLOMIX.
Showing 8 results





Choose Thermostatic – Your project needs a visible, user-operable thermostatic mixing tap at an individual basin, hob or shower point-with an integrated thermostatic cartridge and lever handle.
Choose Thermostatic Mixer Taps instead – If your project specifies a wall- or hob-mounted single-lever thermostatic mixer with an integrated body.
Choose Thermostatic Mixing Valves / FLOMIX instead – If your application requires a hidden zone-level TMV installed in a wall cavity or plant room serving multiple outlets, with NSW Health Approval and stainless steel lockable enclosure.
Public Hospitals – Patient ward hand-wash basins | AS 4032.1 ≤45°C; NSW Health TMV Policy
Aged Care – Ensuite and common bathroom basins | Aged Care Quality Standards Standard 2; AS 4032.1
Disability/Accessible Housing – Accessible bathroom basins (NCC D3.6) | DDA/AS1428.1 lever geometry; NCC 2022
Corrections / Mental Health – Secure ward basins – anti-ligature specification | AS1428.1; facility-specific anti-ligature spec
Defence Health Facilities – Clinical basin and shower outlets (e.g. Darwin RAAF – verified project) | Defence Infrastructure Guidelines; AS/NZS 3500
Education – Science labs, ablution block | AS 3718:2021 performance; WELS rating required
Childcare – Children’s basin outlets | AS 4032.1 scald prevention; state facility standards
Hotels / Serviced Apartments – Guest room basin outlets requiring thermostatic control | WELS compliance; NCC 2022 G6 water efficiency
Jabiru Medical Centre – Listed as using ‘Point of Use Thermostatic Tapware’ – consistent with TEMPSET tapware range
Darwin RAAF Health Command – Listed as using ‘Point of Use Thermostatic Tapware’ – defence health facility application
Alfred Health – Paula Fox Melanoma and Cancer Centre – NUGEN Shower Mixers and SMARTEC Tapware – healthcare thermostatic tapware application
Maitland Private Hospital – Oncology & Mental Health Wards – CLEANLINE, NUGEN & SMARTEC Tapware – mixed clinical environment application
The Canberra Hospital – SMARTEC Tapware – healthcare facility
Thermostatic tapware incorporates a thermostatic cartridge that automatically maintains a preset mixed water outlet temperature regardless of fluctuations in supply pressure or temperature, protecting users from scalds while delivering consistent flow.
Yes. Australian hospitals must comply with AS 4032.1, which requires thermostatic mixing devices to maintain water at ≤45°C for patient-facing outlets. NSW Health Approved products are required in NSW public hospital facilities under PD2015_012.
Yes. All thermostatic tapware installed in Australian buildings must carry a WaterMark licence under the Plumbing Code of Australia. Newly manufactured drinking water tapware also requires a Lead-Free WaterMark from 1 May 2026 under NCC 2022.
DDA/AS1428.1:2009 specifies minimum lever lengths for accessible facilities. Gentec TEMPSET models MVPMLF30150 and MVPMLF10150 carry 150mm levers.
A point-of-use thermostatic mixing tap can replace a TMV at individual outlets in some applications but cannot replace a zone-level TMV conditioning water for a circuit of multiple outlets. Healthcare hot water systems typically use both.
Laminar flow is confirmed for the TEMPSET range (e.g. MVPMLF30150 product description states ‘Laminar Flow’). Laminar flow at the outlet reduces water aerosol generation compared to aerated or spray outlets, a clinical specification requirement for patient-facing basins referenced in NSW Health and ASHRAE 188 guidance. Confirm ‘Laminar Flow’ in the specific product datasheet before specifying for clinical environments, since not every thermostatic tap on the market uses this outlet type by default.
The body material is dezincification-resistant (DZR) brass, a lead-free copper-zinc alloy that resists selective zinc leaching in recirculated hot water. DZR brass is tested to AS 2345 and is the standard material specification for commercial thermostatic tapware in Australian healthcare and aged care projects. The chrome-plated finish over the DZR brass body additionally withstands hospital-grade disinfection protocols, including alcohol-based wipes and hypochlorite solutions, over the product’s service life.
Yes. The MVPMLF20AV is a Lead-Free DZR Brass wall-mounted point-of-use thermostatic mixing basin tap with an anti-ligature control, extending specification into corrections, mental health and secure wards where standard lever handles pose a ligature risk. It remains part of the same compliant DZR brass product family as the standard TEMPSET models, so specifiers do not need to source a separate anti-ligature supplier for mixed-use facilities.
Yes, subject to correct set-temperature specification. AS 4032.1 requires thermostatic mixing devices for vulnerable-person environments, including children, to deliver water at ≤45°C. Confirm the set point with a licensed plumber, engage them for installation, and verify compliance with the relevant state’s childcare facility standards before finalising the specification for a childcare project, since some states impose additional requirements beyond the national standard.